; M7-2719.ASM - California Computer Systems 2719 2 Serial/ 2 Parallel ; Input/Output Board Dennis Recla 01/04/84 ; ; ; You will want to look this file over carefully. There are a number of ; options that you can use to configure the program to suit your taste. ; ; Much of the information contained here is not in the MDM7xx.ASM file. ; ; Edit this file for your preferences then follow the "TO USE:" example ; shown below. ; ; Use the "SET" command to change the baudrate when desired. It starts ; out at 300 baud when the program is first called up. ; ; TO USE: First edit this file filling in answers for your own ; equipment. Then assemble with MAC.COM or equivalent ; assembler. Then use 'DDT' to overlay the results of ; this program to the original .COM file: ; ; = = = = = = = = = = = = = = = = = = ; ; ; A>DDT MDM7xx.COM ; DDT VERS 2.2 ; NEXT PC ; 4300 0100 (May vary with Newer Versions) ; -IM7-2719.HEX (note the "I" command) ; -R ("R" loads in the .HEX file) ; NEXT PC ; -G0 ; A>SAVE 66 MDM7xx.COM (now have a modified .COM file) ; ; ^- May vary with new versions of MDM7xx.COM ; ; = = = = = = = = = = = = = = = = = = ; ; 01/04/84 - New Version for CCS 2719 Board - Dennis Recla ; ; ; = = = = = = = = = = = = = = = = = = ; BELL: EQU 07H ;Bell CR: EQU 0DH ;Carriage return ESC: EQU 1BH ;Escape LF: EQU 0AH ;Linefeed ; YES: EQU 0FFH NO: EQU 0 ; ; PORT: EQU 50H ;CCS Board Base Port Address MODCTL1: EQU PORT+5 ;Serial A Modem control port MODDATP: EQU PORT+4 ;Serial A Modem data port BAUDRP: EQU PORT ;Baud rate port MODRCVB: EQU 01H ;Your bit to test for receive MODRCVR: EQU 01H ;Your value when receive ready MODSNDB: EQU 04H ;Your bit to test for send MODSNDR: EQU 04H ;Your value when send ready ; LSBAUD: EQU 07H ;default baud rate (least signif. byte) MSBAUD: EQU 34H ;default baud rate (most signif. byte) ; ORG 100H ; ; ; Change the clock speed to suit your system ; DS 3 ;(for "JMP START" instruction) ; PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H SMARTMODEM: DB NO ;yes=HAYES Smartmodem, no=non-PMMI 104H TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H CLOCK: DB 40 ;clock speed in MHz x10, 25.5 MHz max. 106H ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc. MSPEED: DB 1 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H ;6=2400 7=4800 8=9600 9=19200 default BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H ;default time to send character in ter- ;minal mode file transfer for slow BBS. CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H ;default time for extra wait after CRLF ;in terminal mode file transfer NOOFCOL: DB 5 ;number of DIR columns shown 10AH SETUPTST: DB YES ;yes=user-added Setup routine 10BH SCRNTEST: DB YES ;cursor control routine 10CH ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH ;no=resend a record after a valid NAK BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH CRCDFLT: DB YES ;yes=default to CRC checking 10FH TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H CONVBKSP: DB NO ;yes=convert backspace to rub 111H TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H ADDLF: DB NO ;no=no LF after CR to send file in 113H ;terminal mode (added by remote echo) TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H TRANLOGON: DB NO ;yes=allow transmission of logon 115H ;write logon sequence at location LOGON SAVCCP: DB YES ;yes=do not overwrite CCP 116H LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H ;no=external command if EXTCHR precedes TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H LSTTST: DB YES ;yes=printer available on printer port 119H XOFFTST: DB NO ;yes=check for XOFF from remote while 11AH ;sending a file in terminal mode XONWAIT: DB NO ;yes=wait for XON after CR while 11BH ;sending a file in terminal mode TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH EXTRA1: DB 0 ;for future expansion 11EH EXTRA2: DB 0 ;for future expansion 11FH BRKCHR: DB '\'-40H ;^\ = Send a 300 ms. break tone 120H 20H NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H LOGCHR: DB 'L'-40H ;^L = Send logon 122H LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H EXTCHR: DB '^'-40H ;^^ = Send next character 127H ; ; DS 2 ; 128H IN$MODCTL1: MVI A,10H ;channel 0, reset interrupts 12AH OUT MODCTL1 IN MODCTL1 ;get the status bits RET DS 3 ; OUT$MODDATP: OUT MODDATP ! RET ;out modem data port 134H DS 7 IN$MODDATP: IN MODDATP ! RET ;in modem data port 13EH DS 7 ANI$MODRCVB: ANI MODRCVB ! RET ;bit to test for receive ready 148H CPI$MODRCVR: CPI MODRCVR ! RET ;value of receive bit when rdy 14BH ANI$MODSNDB: ANI MODSNDB ! RET ;bit to test for send ready 14EH CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H DS 6 ; 154H OUT$MODCTL1: OUT MODCTL1 ! RET ;out modem control port #1 15AH OUT$MODCTL2: NOP ! NOP ! RET ;out modem control port #2 15DH ; ; LOGONPTR: DW LOGON ;for user message. 160H DS 6 ; 162H JMP$GOODBYE: JMP GOODBYE ; 168H JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH RET ! NOP ! NOP ;(by-passes PMMI routine) 171H RET ! NOP ! NOP ;(by-passes PMMI routine) 174H JMP$SETUPR: JMP SETUPR ; 177H JMP$SPCLMENU: JMP SPCLMENU ; 17AH JMP$SYSVER: JMP SYSVER ; 17DH JMP$BREAK: JMP SENDBRK ; 180H ; ; ; Do not change the following six lines. ; JMP$ILPRT: DS 3 ; 183H JMP$INBUF DS 3 ; 186H JMP$INLNCOMP: DS 3 ; 189H JMP$INMODEM DS 3 ; 18CH JMP$NXTSCRN: DS 3 ; 18FH JMP$TIMER: DS 3 ; 192H ; ; ; Clear sequences -- CLREOS is clear to end of screen, CLRSCRN is clear ; entire screen. Last entry must be 0. Any other 0's act as NOP's. ; ; Set Up for Televideo Terminal ; CLREOS: CALL JMP$ILPRT ; 195H DB ESC,'Y',0,0,0 ; 198H RET ; 19DH ; CLRSCRN: CALL JMP$ILPRT ; 19EH DB ESC,'*',0,0,0 ; 1A1H RET ; 1A6H ; ; SYSVER: CALL JMP$ILPRT ; 1A7H DB 'Version for CCS 2719 I/O Serial Port A ' DB CR,LF,0 RET ;..... ; ; ;----------------------------------------------------------------------- ; ; NOTE: You can change the SYSVER message to be longer or shorter. The ; end of your last routine should terminate by 0400H (601 bytes ; available after start of SYSVER) if using the Hayes Smartmodem ; or by address 0C00H (2659 bytes) otherwise. ; ;----------------------------------------------------------------------- ; ; You can put in a message at this location which can be called up with ; CTL-O if TRANLOGON has been set TRUE. You can put in several lines if ; desired. End with a 0. ; ; LOGON: DB 'Hello.. Hello.. Anyone Around ??? ',CR,LF,0 ;..... ; ; ; This routine allows a 300 ms. break tone to be sent to reset some ; time-shar computers. ; SENDBRK: MVI A,5 OUT MODCTL1 MVI A,0F8H ;SEND A BREAK TONE JMP GOODBYE1 ;..... ; ; ; This routine sends a 300 ms. break tone and sets DTR low for the same ; length of time to disconnect some modems such as the Bell 212A, etc. ; GOODBYE: MVI A,5 OUT MODCTL1 ;SEND TO THE STATUS PORT MVI A,68H ;TURN OFF DTR ; GOODBYE1: OUT MODCTL1 MVI B,3 ;WAIT FOR 300 MS. CALL JMP$TIMER MVI A,5 OUT MODCTL1 MVI A,0E8H ;RESTORE TO NORMAL, 8 BITS, DTR ON, ETC. OUT MODCTL1 RET ;..... ; ; ; CCS 2719 Port initialization ; INITMOD: MVI A,0 ;SELECT REGISTER OUT MODCTL1 MVI A,18H ;THROW OUT OF MODE OUT MODCTL1 MVI A,04H ;SELECT REGISTER OUT MODCTL1 MVI A,44H ;SET ASCII PARAMETERS OUT MODCTL1 MVI A,03H ;SELECT REG. OUT MODCTL1 MVI A,0C1H ;ENABLE RECEIVE OUT MODCTL1 MVI A,05H ;SELECT REG. OUT MODCTL1 MVI A,0EAH ;ENABLE SEND, 'DTR', 'RTS' OUT MODCTL1 ; INITMOD1: MVI A,1 ;DEFAULT TRANSFER TIME TO 300 BAUD STA MSPEED ; INITMOD2: MVI A,LSBAUD ;SET "LSP" TO BAUD RATE OUT BAUDRP ; INITMOD3: MVI A,MSBAUD ;SET "MSP" TO BAUD RATE OUT BAUDRP RET ;..... ; ; ; Setup routine to allow changing modem speed with the SET command. ; SETUPR: LXI D,BAUDBUF ;POINT TO NEW INPUT BUFFER CALL JMP$ILPRT DB 'Input Baud Rate (300,600,1200,2400,4800,9600,19200): ',0 CALL JMP$INBUF LXI D,BAUDBUF+2 CALL JMP$INLNCOMP ;COMPARE BAUDBUF+2 WITH CHARACTERS BELOW DB '300',0 JNC OK300 ;GO IF GOT MATCH CALL JMP$INLNCOMP DB '600',0 JNC OK600 CALL JMP$INLNCOMP DB '1200',0 JNC OK1200 CALL JMP$INLNCOMP DB '2400',0 JNC OK2400 CALL JMP$INLNCOMP DB '4800',0 JNC OK4800 CALL JMP$INLNCOMP DB '9600',0 JNC OK9600 CALL JMP$INLNCOMP DB '19200',0 JNC OK19200 CALL JMP$ILPRT ;ALL MATCHES FAILED, TELL OPERATOR DB '++ Incorrect entry ++',CR,LF,BELL,0 JMP SETUPR ;TRY AGAIN ; OK300: MVI A,1 ;MSPEED VALUE FOR FILE TRANFER TIME LHLD BD300 JMP LOADBD ; OK600: MVI A,3 LHLD BD600 JMP LOADBD ; OK1200: MVI A,5 LHLD BD1200 JMP LOADBD ; OK2400: MVI A,6 LHLD BD2400 JMP LOADBD ; OK4800: MVI A,7 LHLD BD4800 JMP LOADBD ; OK9600: MVI A,8 LHLD BD9600 JMP LOADBD ; OK19200: MVI A,9 LHLD BD19200 ; LOADBD: STA INITMOD1+1 ;CHANGE TIME-TO-SEND TO MATCH BAUDRATE MOV A,L ;GET "LSP" BAUD RATE BYTE STA INITMOD2+1 ;SEND TO 8253 TIMER FOR NEW BAUDRATE MOV A,H ;GET "MSP" BAUD RATE BYTE STA INITMOD3+1 JMP INITMOD1 ;REINITIALIZE TO NEW BAUDRATE, THEN DONE ;..... ; ; ; Table of baud rate values ; BD300: DW 3407H ;300 baud BD600: DW 0C047H ;600 baud BD1200: DW 6047H ;1200 baud BD2400: DW 3047H ;2400 baud BD4800: DW 1847H ;4800 baud BD9600: DW 0C47H ;9600 baud BD19200: DW 0647H ;19200 baud ; BAUDBUF: DB 10,0 DS 10 ;..... ; ; ; The following routine can be used as an auxiliary menu for notes of ; interest to a particular computer, etc. If using the Hayes Smartmodem ; this is unavailable without a special address change. ; SPCLMENU: RET ;..... ; ; ; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem) ; 0C00H (without Smartmodem) ; END ;